Full Bridge Inverter: Circuit, Waveforms, Working And Applications

             

Full Bridge Inverter: Circuit, Waveforms, Working And Applications





In this series, we will see the working principle of power inverters. It is an electrical device that can convert a DC signal into an AC signal with respect to standard magnitude and frequency. It is also called a DC to AC Power Converter. Power inverters are two types according to the characterization that is single phase inverter and three-phase inverter. Single-phase inverters are classified into two types, i.e. half bridge inverter and full bridge inverter.

Content

1. What is a Single-Phase Full Bridge Inverter?
2. Classification of Power Inverter
     2.1 Output Characteristics
     2.2 Source of the Inverter
     2.3 Type of Load
     2.4 PWM Technique
     2.5 Number of Output Levels
3. Circuit Diagram
4. Working Principle of Full Bridge Inverter
5. Important Formula
6. Advantages of Full Bridge Inverter
7. Disadvantages of Full Bridge Inverter
8. Applications of Full Bridge Inverter
9. Difference Between Full Bridge And Half Bridge Inverter



What is a Single-Phase Full Bridge Inverter?

A single-phase full bridge inverter is a switching device that generates a square wave AC voltage in the output on the application of DC voltage in the input by adjusting the switch ON and OFF. The voltage in the output of a full bridge inverter is either -VDC,+VDC or 0.

Classification of Power Inverter

According to classification, inverters are five types.

Output Characteristics

  • Square Wave Inverter
  • Sine Wave Inverter
  • Sine Wave Inverter 

Source of the Inverter

  • Current Source Inverter
  • Voltage Source Inverter

Type of Load

Single-Phase Inverter

  • Half Bridge Inverter
  • Full Bridge Inverter

Three Phase Inverter

  • 180-Degree Mode
  • 120-Degree Mode

PWM Technique

  • Simple Pulse Width Modulation
  • Multiple Pulse Width Modulation
  • Sinusoidal Pulse Width Modulation
  • Modified Sinusoidal Pulse Width Modulation

Number of Output Levels

  • Regular Two-Level Inverter
  • Multi-Level Inverter

Circuit Diagram




Working Principle of Full Bridge Inverter

So this is the circuit that converts DC to AC only for a single-phase system. So if you’re having a single-phase load, you will be able to convert DC to AC by having this type of circuit. One important thing to remember while analyzing this type of circuit is the polarity of the load. So if the current is flowing from A to B the current is assuming as positive and if A is positive concerning B then the voltage is also positive. this convention is very very important because this will be very useful for us to understand the waveforms. So how to analyze this type of circuit.

Case 1: When the switches T1 and T2 are ON

Next, I will be assuming switches T3 and T4 are returned on, while provider T1 and T2 are turned off so the circuit looks like this.



T3 and T4 access short circuit. Current starts flowing through the supply from here ( a 🠒 b 🠒 c 🠒 d 🠒 e 🠒 f ) and returns to the source.

Now what happens is that the output current is negative because it is flowing from B to A according to our convention, it is in the opposite direction. As a result, we are taking it as negative and if you carefully observed output voltage is also negative. So as a whole VS is supplied and that directly appears across the load terminal.

So if you carefully observed that (+) is directly connected to B, so it is positive and (-) is directly connected to A. As a result, you will be getting the output voltage to be equal to -VS.

So once we know the values of voltages and currents that will be there in the circuit, now how is the conversion of DC to AC achieved. It can be analysed through waveforms. Now let us look into the getting pulses of T1 and T2. So I’ll be triggering T1 and T2 and I’ll be turning off for the remaining duration. T3 and T4 will be done only when T1 and T2 are turned off. The reason is very simple, if you’re turning them all together, then the entire circuit will be shorted and you’ll not be getting any of the output and their chances that the supply also will get damaged.


How do the output voltage and current waveform look like?


So it looks like this, when T1 and T2 are turned on and the output voltage is (+) VS. Consequently once T1 and T2 are turned off and T3 and T4 are turned on, the voltage or current will immediately change to (-) VS according to the inference that we have noted down with respect to case 2.

Again in the next cycle, when T1 and T2 are triggered, the output voltage will be equal to (+) VS. The voltage across the load will basically the supply voltage, so it changes instantly. As a result, there will be no deviations where it increases slowly or decreases slowly. So this is for a resistive load, as a result, it will change instantly.

If we want to build an AC supply i.e. in our household applications, requires pure sinusoidal AC. So we cannot directly give the circuit to our household appliances. For this, we need to convert a square wave to a sinusoidal waveform. By doing this, we need to use filters in order to achieve that.

Important Formula

1. The conduction angle of each diode is φ.

2. The conduction angle of each Thyristor is π – φ.

3. Self-commutation is possible only in leading power factor load or underdamped system at circuit turn off time tc = φ / w0; where w0 is the fundamental frequency.

4. Fourier series V0 (t) = ∑n=1,3,5α [ 4 VDC/ nπ ] Sin nw0t.

5. I0 (t) = ∑n=1,3,5α [ 4 VDC / nπ l zn l ] Sin nw0t + φn.

6. V01max = 4 Vdc / π.

7. I01max = 4 VDC / πZ1.

8. l zn l = R2 + ( nw0L – 1/ nw0C) ; where n = 1,2,3,4…

9. φn = tan -1 ( 1 / R ).

10. Fundamental Displacement factor FDF = cos φ.

11. Diode current equation ID and waveform is:
ID01 (avg) = 1/2π [ ∫0φ I01 max Sin ( w0t – φ1 ) ] dwt
ID01 (rms) = [ 1/2π [ ∫0φ I01 max2 Sin2 ( w0t – φ1 ) dwt ] ]1/2

12. Switch or thyristor current equation IT and waveforms is:
IT01 (avg) = 1/2π [ ∫φπ I01 max Sin ( w0t – φ1 ) ] dwt
IT01 (rms) = [ 1/2π [ ∫φπ I01 max2 Sin2 ( w0t – φ1 ) dwt ] ]1/2



Advantages of Full Bridge Inverter

  • There is the minimal fluctuation of voltage in the circuit.
  • It is also suitable for high input voltage.
  • Energy-Efficient.
  • The current rating of the circuit is equal to the load current.
  • It drives slightly more voltage ripples than half bridge inverter.

Disadvantages of Full Bridge Inverter

  • The efficiency of the full bridge inverter ( 95% ) is less than the half bridge inverter (99%).
  • Losses and noise are high, so it requires more switching elements.
  • It is analogous to the half bridge inverter. However, it’s an extra segment to attach the ground point to the load.

Applications of Full Bridge Inverter

  • This is used in the application of a higher voltage requirement.
  • It can be applicable in low and medium power example square wave / quasi square wave voltage.
  • Solar inverters can use this type of power inverter.
  • It also uses in this type of devices like AC variable motor, heating induction device, standby power supply etc.

Difference Between Full Bridge And Half Bridge Inverter


Parameter Full Bridge Inverter Half Bridge Inverter
The number of devices conducting simultaneously. Two One
The number of power electronics switches used. Four Two
Efficiency Lower than half bridge inverter (95%) High (99%)
Noise High Lower than Full Bridge Inverter
The maximum value of output voltage Peak voltage is half of the DC supply voltage Peak voltage is the same as the DC supply voltage